Guaranteed Salt Not Recommended: Rock salt, high in impurities, block, granulated, table, ice melting, ice cream making salts, etc., are not recommended.Salt with Iron Removing Additives: some salts have an additive to help a water conditioner handle iron in a water supply.

After the water stands for a period of time, the particles settle to the bottom of the container. Due to high order volumes, some products are out of stock. This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. When the salt bridges, an empty space forms between the water and the salt. 50-52), Drain Hose Adaptor Kit (includes Key Nos. This creates a bigger cavity for the salt and is one of a few ways to add salt.Step 4: Remove top cap.Step 5: Add the correct amount of tablesaltinto the top for your softener.- One full 26 oz. This water softener will not remove ferric or bacterial iron. Install the brine tank overflow grommet and elbow into the 13/16 diameter hole in the back of the salt. Plug the inlet and outlet with clean rags to keep dirt, bugs, etc. remove the material from inside the tank. If an error code shows, first press the SELECT button to enter the diagnostic display. This flushes any resin dust out.

All plumbing must be completed in accordance with national, state, and local plumbing codes. If the time is flashing after a long power outage, the softener continues to work as it should to provide you with soft water. Step 10. Lift the salt lid and level the salt in the storage tank. Be sure AM or PM is correct. Take off both drain hoses if they will interfere with moving the softener into position ver the drain. This warranty applies to consumer-owned installations only. ), Distributor O-Ring Kit (includes Key Nos. 1. Recharge NowAt times of greater than normal water use, such as when you have guests, you could run out of conditioned water before the next scheduled recharge. Press the SELECT button twice, so that bA TIME appears in the display (See Figure 27). In the state of California: You must turn the Salt Efficiency Feature setting to ON. NOTE: If - - shows in the display, press the UP or DOWN button until the model code (see table n age 5) shows in the display. Iron in water is measured in parts per million(ppm). Be sure to use the included power supply and plug it into a nominal 120V, 60 Hz household outlet that is in a dry location only, grounded, and properly protected by an overcurrent device such as a circuit breaker or fuse. NOTE: Inlet and outlet are marked on the water softener valve. Step 1: Disconnect both hoses and turn the unit upside down and allow water to drain from inlet/outlet. If you wish to turn the Salt Efficiency feature ON ( icon will show in the display), follow the instructions on this page. To restore the ground, do the following: 1. Consult with your licensed plumber. Press the RECHARGE button to move the softeners valve into the backwash position. European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic, Colloidal and inorganically bound iron (ferrous or ferric). To avoid the loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them. Step 1: Turn off the water supply.Step 2: Disconnect inlet andoutlet hose from thesoftener.Step 3: You can drain water by tilting unit over or turning it upside down with the head/cap ON. Whether youre looking to remove iron and fight buildup or extend your water softeners life, Morton has the right salt for you. If you have questions regarding a Morton water softener or MWSC, need assistance with installation or troubleshooting, wish to order a part, or report a warranty issue, we are just a phone call away. Chlorination is also recommended for bacterial iron. These softeners were efficiency rated according to NSF/ANSIStandard 44. Avoid installing in direct sunlight.

(If the flow completely stops, turn the water off, tap the tank against the ground to get the resin to fall back down, and turn the water on 75% full stream.)

Be sure to clean both the top and bottom of the nozzle & venturi disc.

Carefully replace all parts in the correct order. Make the valve drain line as short and direct as possible. Put the bypass valve(s) into the bypass position. When the desired Fast Rinse time appears in the display, press the SELECT button once to return to the normal run (time of day) screen. For a period of one (1) year from the date of purchase, all other parts will be free of defects in material and workmanship. Refer to warranty and elsewhere in this manual for further details on installation and maintenance, parts and service, user responsibility, and further restrictions, or limitations to the use of the product. 25,500 @ 8.0 lbs. Leave an air gap of 1-1/2 between the end of the hose and the drain. How many gallons a softener will approximatelymake depends on the hardness of the water source and your waterusage. When completed, full water conditioning capacity is restored. For a period of ten (10) years from the date of purchase, the salt storage tank and fiberglass mineral tank will not rust, corrode, leak, burst, or fail to perform to their specifications. Then, remove the nozzle & venturi disc, gasket, and flow plug(s). WARRANTORS SOLE LIABILITY FOR ANY PRODUCT IS LIMITED TO THE REPAIR OR REPLACEMENT OF SUCH PRODUCT, OR A REFUND OF THE PURCHASE PRICE ACTUALLY RECEIVED BY WARRANTOR FOR SUCH PRODUCT, AT WARRANTORS SOLE DISCRETION.

Move the stem in the single bypass valve to bypass. Check the brine well to be sure it is secured and vertical (see Figure 11). If you want to change the recharge start time, press the. CAUTION: The house cold water pipe (metal only) is often used as a ground for the house electrical system, The 3-valve bypass type of installation, shown in Figure 8, will maintain ground continuity. 73 & 74, Nozzle & Venturi Assembly (includes Key Nos. Press and hold the SELECT button until the model code (see table on page 5) shows in the display. Set Time of DayIf the words PRESENT TIME do not show in the display, press the SELECT button until they do. Step 5: After the recommend amount of time, turn the water off and hook the softener back up.Note: If Back-flush and Re-gen are done together, perform theBack-flush processfirst.

When completed (in about 2 hours), full water conditioning capacity is restored.NOTE: Avoid using hot water while the softener is regenerating, because the water heater will refill with bypass hard water. The total* ppm of iron, and type or types*, is determined by chemical analysis. Secure drain hose. This will also assure that the softener is completely recharged and ready to provide softened water again. Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level. A floor drain, close to the water softener, is preferred. Place the single bypass valve or 3 valve bypass in the bypass position. Observe the highest number the leveled salt is at, or closest to. Check for leaks around clips at the softeners inlet and outlet. Press the SELECT button three times, so that SET TIME Fr appears in the display (See Figure 42). Press the.

Set them aside to prevent damage. During regeneration, the word RECHARGE NOW will flash on the screen. Recommended Salt: We recommend using Morton Clean and Protect Plus Rust Defense or clean and Protect Pellets in the familiar yellow bag. However, during shipping, storage, installation, and operation, bacteria could get into the unit. If the storage tank is full of salt, it is difficult to tell if you have a salt bridge. 5600sxt softener fleck valve programming button water efficiency max buttons enter controller master menu Shut off the electric or fuel supply to the water heater. Run the drain hose (or a rigid line) to the floor drain. Before placing the unit in storage or being idle for extended periods: Alaundry tub, standpipe, etc. Forboth optionsDO NOT REMOVE top cap or head. Be sure to provide a 1-1/2 minimum air gap to prevent possible sewer water backup. Hold the buttons down for fast advance.Step 2. Air Gap RequirementsA drain is needed for the water discharged from the valve during the softeners regeneration cycle (See Figure 3). In Massachusetts, plumbing codes of Massachusetts shall be conformed to. measure the distance from the floor to the rim of the water softener. Press the UP or DOWN buttons to set the present time. softener culligan kenmore This may initiate more frequent recharges. NOTE: You must set salt level each time salt is added to the water softener. Outside faucets should remain. To turn on the Salt Efficiency Feature, follow the instructions in the Salt Efficiency section of this manual. EXTEND YOUR WARRANTY: Use MortonMWSC Water Softener CleanserThe factory warranty for your water softener is shown below.

Simply dial 1- 8864WATER (1-888-649-2837) for assistance, or visit www.mortonwatersofteners.com. 23,700 @ 7.0 lbs. To reset the timer, press any button on the control panel and CLEAn will disappear. Then, press the SELECT button to set, and change to the flashing SET IME display. Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time based on the amount needed. To have fully conditioned hot water immediately, wait until the initial recharge (Step 12) is over. The softener is shipped withthis feature set OFF. Press and hold the SELECT button until the screen in Figure 26 is displayed. Set Time of DayIf the words SET TIME do not show in the display, press the SELECT button until they do. Your email address will not be published. In this example, you would use 30 for your hardness number. 1-3), Tank Neck Clamp Kit (includes Key Nos. Replace the brinewell cover. Carefully push into the bridge in several places to break it. Place bypass valve(s) in service or soft water position exactly as follows: After about three minutes, open a hot water faucet until there is a steady flow and there are no air bubbles, then close this faucet. Press the RECHARGE button and hold in for 3 seconds. Step 4: Unit is ready for storage. 5600sxt softener fleck valve programming button water efficiency max buttons enter controller master menu Operational efficiency is the actual efficiency after the system has been installed. Press the SELECT button three times, to return to the normal run display (See Figure 37). Excessive sun heat may cause distortion or other damage to metallic parts. Using a container, add about three gallons of clean water into the salt storage tank. Be sure AM or PM is correct. Up moves the display ahead; down sets the time back.

Procedure for removing error code from display: Manual Advance DiagnosticsUse the following procedures to advance the water softener through the regeneration cycles to check operation.

The Proper Order To Install Water Treatment Equipment. ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE RE HEREBY DISCLAIMED. Systems tested and certified by NSF Inter nation against NSF/ANSI Standard 44 for hardness reduction and efficiency, and certified to NSF/ANSI Standard 372. It is usually caused by high humidity or the wrong kind of salt. However, it will operate at 4,000 grains per pound of salt or higher. 28,100 @ 11.2 lbs. The maximum allowable inlet water pressure is 125 psi.

): Manual Advance Regeneration CheckThis check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Do not scratch, misshape, etc., surfaces of the nozzle & venturi. Move the softener close to the drain. Separate the softener from the plastic installation adaptors, or from the bypass valve. Remove the brinewell cover and, using a flashlight, observe fill water entering the tank. Avoid elevating the hose more than 8 feet above the floor. Always make the initial checks, and the manual initiated diagnostics. Make sure that the tabs are fully seated. softener softeners To change the length of the Backwash: Low Salt Light / Clean ReminderWhen the water softener is connected to electrical power, the light on the control panel will operate as follows: This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. Overtightening may break the cap or housing. softener water barista espresso recharging manual Plugin the Power SupplyDuring installation, the water softener wiring may be moved or jostled from the place. Add Morton System Saver II Pellets to the storage tank. This softener setting is shipped in the OFF position, which utilizes the maximum rated capacity while most often achieving maximum salt efficiencies. You may damage the tank. Power Outage MemoryIf electrical power to the softener is interrupted, the time display is blank, but the electronic controller keeps the correct time for several hours. While in this diagnostic screen, the following information is available and may be beneficial for various reasons. Press and hold the RECHARGE button until the words RECHARGE NOW flash in the display.

Trace the water flow direction to be sure hardwater is to the inlet. This information is retained by the computer from the first time electrical power is applied to the electronic controller. Open a faucet in the soft water pipes to vent pressure in the softener. see one bottle of Morton MWSC Water Softener Cleanser, as directed, every four months from the date of purchase of the water softener. Lay a piece of 2-inch thick board near the floor rain (See Figure 45). *Let sit for 60 seconds max, turn water on full for 10 minutes to flush the Sani-System out of the unit. / max. Press and hold the SELECT button until the screen in Figure 40 is displayed. Step 1. Morton Water Softener Salt Pellets are made with a time-release formula that works with your softener to help prevent mineral buildup and keep your homes pipes and appliances working at their best. For the Double Standard model, use two gallons of the solution with your unit.Step 3: Connect the water source to the inlet of the unit, and then remove the top cap. For this reason, sanitizing as follows issuggested* when installing. Recharge TonightIf you do not want to start an immediate recharge, but would like an extra recharge at the next preset recharge time, do the following to schedule a recharge: The words RECHARGE TONIGHT flash in the display, and the softener will charge at the next preset recharge time (If you decide to cancel the regeneration before it begins, press and release the RECHARGE button once more, and RECHARGE TONIGHT will disappear from the display). If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum.

A nearby drain is needed to carry away regeneration discharge (drain) water. Complete Inlet and Outlet Plumbing. sift out the screen support and screen. Remember to fill your water softener with Morton Americas #1 Brand of Water Softener Salt! Close the inlet and outlet valve in a 3 valve bypass system, and open the bypass valve. Be sure the water softener is in the soft water (service) cycle (no water pressure at nozzle & venturi). Do not use any sharp or pointed objects as you may puncture the brine tank. Step 6. To get access to the nozzle & venturi, remove the water softeners top cover. Step 1. Thoroughly check the water softener for possible shipping damage and parts loss. softener softeners To condition all water in the home, install the water softener close to the water supply inlet, and upstream of all other plumbing connections, except outside water pipes. Any other installed water conditioning equipment should be installed between the water inlet and water softener (See Figure 4 below). Remove the softeners top cover, together with the alt lid.

The salt level scale, on the brinewell inside the tank, has numbers from 0 to 8 (See Fig. Breaking a Salt BridgeSometimes, a hard crust or salt bridge forms in the brine tank. The foregoing warranties do not cover and Warrantor shall not be responsible for reimbursement for labor, transportation, removal, installation, or other expenses which may be incurred by Purchaser in connection with replacement or repair or return the product to Warrantor. Be sure the hard water supply pipe goes to the water softener valve inlet side. This will prevent whipping during regenerations. Snap the two large holding clips into place, from the top-down as shown in Figures 12 & 13. Plumb a rigid drain as needed (see Figure 6). Step 2: Use thefemale/female adapter (not labeled) to the outlet of the softener. Again look for a fast drain flow. NOTE: The electronic control display must show a steady time (not flashing). Check the water level in the tank by looking down the brinewell. NO WARRANTOR DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND, EXPAND OR MODIFY THE WARRANTIES EXPRESSLY DESCRIBED ABOVE. Pour the solution into the tank, and put top cap back on. Do not try to break the salt bridge y pounding on the outside of the salt tank. For soft water, nothing works harder.

Resetting to Factory DefaultsTo reset the electronic controller to its factory default for all settings (time, hardness, etc. Press and hold SELECT for 3 seconds until 000 shows in the display, then release. Place the brine valve back into the bottom of the brinewell and reinstall the brinewell cover. Colloidal iron water usually has a yellow appearance when drawn. Immediately after taking, the sample is clear. At the end of the regeneration process the water should also not have a salty taste.Step 9: Regeneration cycle is complete. Do not locate the water softener where freezing temperatures occur. Electronic Control Board (PWA), Model M34, Brinewell Assembly (including salt level decal), Model M34, Brinewell Mounting Hardware Kit (includes Key Nos. If your home is equipped with a backflow preventer, an expansion tank must be installed in accordance with local codes and laws. Program the SoftenerWhen the power supply is plugged into the electrical outlet, the model code and a software version number (example: J3.9), are briefly shown in the display.

of Key Nos. Install and tighten the cap by hand, while supporting the housing. Call Toll Free 1-888-64 WATER (1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Make sure the float stem is parallel to the stand tube so the seals will seat properly during operation. Also, inspect and note any damage to the shipping carton. See Set Salt Level on Page 17. This should take at least 20 minutes. Open all faucets to drain all water from house pipesNOTE: Be sure not to drain water from the water. Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose), Water Used During Regeneration @ Minimum Salt Dose, Total Water Used Per Regeneration @ Maximum Salt Dose, Amount of High Capacity Ion Exchange Resin, Water and Ambient Temperature Limits (min. For the Standard model, use only one gallon of the solution with your unit and discard the rest per Sani-System instructions. Adjustable BackwashIf your incoming water supply has higher sediments or clear water iron, a longer Backwash and/or Fast Rinse time may help in keeping the unit cleaner. 72) & 1 ea. Lubricate the O-ring seal with silicone grease and locate it in place. After extended periods of non-use, sanitize the unit by following the instructions below: Step 1: Perform Back-flush, and then completely drain all water from the tank.Step 2: Mix 1 packet (.25 fl oz) of Sani-System with two gallons of water (Sani-System packet cannot be reused). If not already done, put a light coating of silicone grease on the single bypass valve o-rings. Hold the buttons down for fast advance. The current time of day will show in the display. * Water may contain one or more of the four types of iron and any combination of these. Then the words PRESENT TIME appear and 12:00PM begins to flash.NOTE: If - - shows in the display, press the UP or DOWN button until the model code (seetable on page 5) shows in the display. Step 12. If the dash shows, the switch is open. If you want water in the house pipes again, reopen the shut-off valve on the main water pipe. Program the SoftenerWhen the power supply is plugged into the electrical outlet, the model code and a software version number (example: J3.9), are briefly shown in the display. A bridge may be underneath loose salt. Add 5 to the hardness number for each 1 ppm of iron. boxes of iodized/non-iodized salt for the Park ModelSoftener.A few Ways to add Salt- Pour salt into the softener.- Mix salt with warm water and pour the solution into the softener.- Pour salt into the softener while periodically pouring water slowly over it with a cup.In extremely hard conditions, also use 1-2teaspoonsof Super Iron Out for the Standard Model, 2-4teaspoons for the Double Standard Model, and 4-6 teaspoons for the Park Model Water Softener. Customizing Features / Options (Model M34). If a leak occurs at a clip, depressurize the.

immediately when drawn from a faucet because it has oxidized before reaching the home. The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). Sanitizing the SoftenerCare is taken at the factory to keep your unit clean and sanitary. 76, 77 & 79-87). If this happens, you may want to initiate an immediate regeneration, as follows: The softener enters the filling cycle of regeneration right away. To return the softeners valve to the service position, press the RECHARGE button. Back flush your Standard Softener every 3 months for 2-5 minutes, Double Standard Softener for 5-10 minutes, and 10-15 minutes for the Park Model Water Softener. Freezing temperatures or hot water damage voids the warranty. The state of Wisconsin requires additional treatment if the water supply contains clear water iron exceeding 5 ppm.These systems conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated by test data.The efficiency rating is only valid at the stated salt dose. Step 6: Replace cap andinlet hose to inlet side of softener. Leave the softener laying like his until you are ready to use it. water softener pex installing warranty instructions installation Use one or both of our premium formula pellets in any water softener for the best results. minimum tube) and 1/2 tubing from your local hardware store. This is a good time for the recharge to start in most households because water is not in use. 19-21), Overflow Hose Adaptor Kit (includes Key Nos. The light will stop flashing unless the system is also low on salt (see above). This code identifies the oftener model. This iron is visible. Press the SELECT button once again to display a flashing 25 and the word HARDNESS. Consider all of the following when selecting an installation location for the water softener. All other settings are maintained and never require resetting unless the change is desired. 29,200 @ 8.6 lbs. Ferric (red water), and bacterial and organically bound irons are insoluble. Use of any water softener additive rather than Morton MWSC will invalidate any extended warranty coverage. This may take 15 to 20 minutes. Unplug the power supply at the wall outlet. If you go too long before performing the regeneration process, a few things couldhappen: your unit may not last verylong, or, after the regeneration process, the strips will not test between 0-3 GPG at the output of the softener. Set the present time, hardness, etc., as described on pages 13 & 14 (for Models M20, M27, M30 & MC30) or pages 16-18 (for Model M34). When power is restored, you must reset the present time only if the display is flashing. Press the UP or DOWN buttons to set the present time. 13,700 @ 2.7 lbs. *If unable to fit all of solution in the tank at once, fit what you can, let sit for 60 seconds max, flush it out for 60 seconds, drain water from the tank, pour the rest of the solution in, let sit for another 60 seconds max, and then turn the water on full and flush the system for 10 minutes. If you wish to turn the Salt efficiency feature ON ( icon will show in the display), follow the instructions on this page. Without brine, the resin bed is not recharged and hard water will result. A flexible drain hose is not allowed in all localities (check your plumbing codes). The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included).

UNIT contains Cation Exchange Resin that is either light gold or light amber to black spherical beads- DONOTREMOVE RESIN.

Press and release (do not hold) the RECHARGE button. 2. Set Water Hardness Number. Step 4. Set Salt LevelThe water softener has a low salt indicator light to remind you to refill the storage tank with salt. avoid salt bridging. Move the water softener to the desired location. Colloidal and inorganically bound iron is of ferric or errors form that will not filter or exchange out of water. Step 1:Perform a back-flush. softener gpg hardness Look for a fast flow of water from the drain hose. Step 1: Turn off the water feeding the point of application.Step 2: Connect the source water to the inlet of the softener. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe. Use a hose clamp to hold the hose in place. It appears as a small cloudy yellow, orange, or reddish suspended particles. Press the SELECT button three times, to return to the normal run display (See Figure 23).3.