hayward tristar Sometimes, local electric companies have a special program that offers special pricing. Im skipping the program 5 this is where we set up a schedule to actually make this pump turn on and turn off. Thanks again for taking the time to answer. The four buttons on the bottom from left to right. We are also a fiberglass swimming pool dealer and installation company. The pump is shut off until the next time it should run. My answer to the similar comments about overall scheduling still applies to this slimmed-down time period. Also, theres a cleaning mode (on a feature) set to 2500 RPMs. In most scenarios, pool owners establish specifictime frames to operate their pump at high speed to correlate with any functions that require more flow. Also, we have foliage around us so that might contribute to problems, we want it to be as efficient as possible. Quick clean set up is just like everything else in the system you have to select it, set your speed set your time, and normally set it for 10 hours at the high speed setting of the pump in 2500 2350. Gainesville FL +1 (352) 519-3125 Below those are several buttons that serve different functions. do you have a zodiac salt cell? Copyright 2020 INYOpools All rights reserved. However, through trial and error, you can program your variable speed to operate at its highest efficiency for your pool. The great thing about a variable speed pump is that you can run it for 24-hours straight without breaking the bank. This is based on the assumption that your average pool pump has a turnover rate of about 8 to 12-hours. This applies to your home appliances, as well. Reset your breaker to the EasyTouch or simply press the Reset button on the EasyTouch outdoor Load box control. Click here to browse all of our swimming pool equipment, Shop Children's STEM Toys at JR Toy Company. Generally, I run my equipment at 1700 RPMs for 10 hours. I have a hayward vs950 pump on a roughly 13000 gallon pool, roughly 1431 and depth 4-6ft freeform, paramount ozone w/ UV, no spa or heater in central Texas. 1956 SW Main Blvd., 4, Lake City, FL 32025, Jacksonville FL +1 (904) 248-4697 So far thermal mode set from the factory, you just want to check to make sure its correct and that its on. To top this off, we also offer Eco-finish pool refinishing. I appreciate this a lot. You can and should add pool shock at night, though. For a better experience, please enable JavaScript in your browser before proceeding. Unfortunately, were not going to able to tell you if that is good or not based solely on numbers. beeps intex Unfortunately, every pool is different, making it tricky to provide a template-style formula that fits every pool scenario.

Jom can they set it up with a 8 am to 8 am run time everyday? In the long run, does this schedule affects the heat pump , being turned on and off on a daily basis? Small 12,000 gallon pool. This allows us to look at our Flow meter that we install on our DE Filter systems to know whether or not the filter needs to be cleaned or backwashed. 8 10 a.m. High speed (to sweep and skim), 4 4:30 a.m. High speed (3450 RPMs to ensure the pump sufficiently primes- non-peak hours), 4:30 12 p.m. There are a number of options and ultimately you need to find the right timing for your pool and pool equipment. You would look here to find out why its shutting down. Its used to clean the pool when youre out of schedule for example you had a party in the middle of the night and then whenever youre done and you want to start the pool cleaning you would hit quick clean and run through the 10 hour program. "Do Pool Pumps Have to Run All the Time?" Matthew, Most pool pumps are gallons per minute, so divide the GPH by 60 to get how many gallons per minute (GPM). Adjust up or down depending on how satisfied you are with the appearance. Its unnecessary and frankly, it defeats the entire purpose of a variable speed pump. When it comes to the best set up for variable speed pool pumps, it depends on the pool and pool equipment. Im all ears. Timeout used in the feature section to make it where you can actually shut the pump down for predetermined time say 15 minutes half hour or hour. It is being practiced by thousands of pool owners just like you. The cost of generating electricity is highest during peak hours. filters pool sand doctor Im new to pool ownership so I Just need to know if my settings are optimal or whether I need to adjust them. See the light above my fingers thats the green light to tell you that the pump is powered up. Tallahassee FL +1 (850) 296-3622 Once you know your pool's volume, divide that number by eight to get gallons per hour (GPH). I checked the scheduled run time for the Pool setting and it still showed a 24 hour run time (8:00 AM to 7:59 AM, seven days a week) so its not clear to me why the pump was not running this morning even though it seemed to be set to run continuously on a 24 hour cycle. Customer Service & Phone Hours of Operation. This is showing speed once you get to that point and hit select, a black cursor will pop up on one digit use the right left arrows to move back and forth. We want to change that. The previous owner did not seem to be a big swimmer, but she actually did us a favor. closing guardianpoolfence Can you give me a good start point to set up schedule? pentair pool This can include when youre cleaning your pool, operating a salt chlorine generator, or using any water features like jets, in floor cleaners, or waterfalls. pentair vbestreviews At 1725 RPM the Heat pump stops working because of insufficient incomings water. In our area there is a company that will do reverse osmosis treatment of the water to get the TDS out of it.

Toll Free +1 (800) 286-7929, Weekdays Even though they can come with a high up front cost, nothing beats a variable speed pump when it comes to striking a balance between clean water and low energy bills. I live in southern Florida. However, in many cases, customers have to inquire about the program as they do not offer it as a standard alternative. Solar came out and said it might need to be set higher to push water up to solar. If you were to do this now the pump would come on usually within a few minutes after doing this as the EasyTouch will recognize the pump should be on since it is set to be on after am 8 and it is pm 2:41 right now. But I would use the test and see method. Does anyone have any advice? Best Setup For Variable Speed Pumps Depending on where you live and the power company, peaks hours may change. You can do one of two things to get programming out of egg timing mode. Much of the world is experiencing oppressively hot temperatures this summer. The idea is to try and run yourvariable speed pump at the lowest RPMs as possible while still filtering your pool water properly. Most visitors online was 3404 , on Jan 24 2020, Current Sensing Relay for SWG with Variable Speed pump, Error Code Went Away With Lower Pump Speed, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. An alternative to both these options is investing in a new pump. Finally, getting back to one of my original questions, does the filter pump need to be operating (on) when Im running my Zodiac cleaner? Back in selection mode, this pump is set up as speed but you can select this and change from speed to flow or vice versa once youve made your selection press save and hit the back button. What are your recommendations for a schedule to run the variable speed pump at. Save $10 on your first order! Those buttons are set up to be used as push buttons for certain speeds and times. In order to confirm the peak hours in your area, we recommend calling your power company. Once you complete those tasks, you can lower the speed settings. variable pentair speed pool pumps inside pump introduction No one is going to be able to tell you this is right, this is wrong for your pool based solely on some numbers.

Of course, that's only if your pool is properly maintained and that includes running the pump to filter the water. I didnt realize that was for easytouch only. After this it will resume normal 24hr operation ie off at am 7:59 and on at am 8:00 in your case. Join our promotional newsletter and be first to know about upcoming sales, special offers and other promotions - no spam, we promise. Can someone provide a typical schedule? Heres what I have with regards to pool size, and equipment: Pool = 8,000 gallons We have a 7500 gallon in ground pool. Save my name, email, and website in this browser for the next time I comment. How Long Should You Run Your Pool Pump For? filters pool sand doctor I normally hit the stop-start and turn the pump off, the danger of that though is its if you forget to turn the pump back on now its not going to run at schedule. Also, not sure it is a variable speed pool, in Florida, and not here all the time but have a company maintaining the pool. If you start to see dips in chlorine production, you either lengthen the run time during the day or raise the RPMs to allow for a higher turnover rate. Throughout the day, the demand for electricity fluctuates. Ideally, you should run your pump for 24 hours a day, but we know thats unrealistic (and pricey), so lets look for an answer that keeps your pool clean and your wallet full. variable pentair speed pool pumps inside pump introduction You can run it several times a day for short periods of time as long as it runs for about eight total hours in 24 hours, especially in the summer. You can calculate your pool's turnover rate pretty easily. If the cleaner acts as expected, lower the RPM and test the cleaner again. Fwiw I live in southern CA and my Electric bill would be through the roof if I even ran the variable pump for 14 hours at a high rate rpm. The concept is much more complex.).

This article provides cross-reference charts for matching a variable speed motor to your Hayward pool pump. Generally running your pool pump for 12-hours a day is a good option. The only thing I want to show you is that this one thing about time overlap. This is the control panel that has a green light that means theres power to the pump. I was hoping to be able to set it somehow and when add chemicals move to a cleaner setting. beeps intex Closed. Are there any other settings on the EZ touch that I can check to make sure the pool pump is actually set to run for 24 hours or do you have any other suggestions for what the problem may have been? I set the pump to run at 2350rpm for 4 hours and drops to 2000rpms for the remaining 4 hours. Ill show you the panel itself. Before you just turn it on and leave it, let's first talk about what a pool pump actually does. I have Pines and other trees in my backyard and leaves and pine needles are a constant problem getting in the pool (mainly on the surface water). The sun can burn shock off during the hot daytime hours, but you still need to have the pump running to circulate the water. If you use a salt generator you will have to run more on mid speed. Even after refilling the pool and doing a stat up on the chemicals we can seem to keep it clean. Filter Pump = Pentair IntelliPro 4 160 (set for 7:30am-3:30pm @ 1,500 RPM) is it easy touch you have? The program usually offers discounted rates during off-peak hours, like nights and weekends. Also, familiarize yourself with your pool equipment and the minimum GPM each unit mandates for operation. So this allows the technician to clean the pool filter. During the off-season, we aim to turn the water over once. Hello this is Steve Cronin from My Favorite Pool Builder. 8:00 am - 5:00 pm Once in Service Mode it is safe to shut the pump off with the F button. You can see its 40 gallon per minute right now. I run this with the saltwater generator set at 50% for 10 hours. Lets break the equation down a little further: Pool Volume: reach this number by multiplying length by width by average depth. My question relates to adding chemicals. Looking for pool parts? So if you have a 4-bolt pump now by any manufacturer you can buy a inexpensive variable pump in the $400 range and save big $$$.

Midspeed works with most suction cleaners. I suggest getting a solar control to turn your solar heater on and off when the heater requires action from the heater. How long should we set it at a higher speed and how many rpms. if so, are there smaller VS pumps available? Did you know that there are times of the day when electricity is cheaper? This is how you would change it, so if you were at 6 a.m. you would scroll up 12 time to get 6 p.m. once youve done that hit save back and now youre at shut off time. At the moment, I bump up the speed to 2450 when the cleaner is running. But does the pump have to run all the time, as in 24 hours a day? chlorine generator salt pool intellichlor pentair ic40 cell vbestreviews upkeep recycles continuously reducing amount daily create Tip: Dont be afraid to tinker with the RPM settings until you find your pools sweet spot. Its unnecessary and frankly, it defeats the entire purpose of a variable speed pump. 2009 - 2022 Pool Supplies Canada. Click here to browse all of our swimming pool equipment, on sale at the best prices online in Canada with fast shipping! Special Offer on Antivirus Software From HowStuffWorks and TotalAV Security.

The pool was custom-built to our particular specifications as my wife doesnt swim very well so theres no way shell drown; however, she does enjoy using it frequently, but it has to be warm (no lower than 85 degrees). I suggest the latter because of the absence of guesswork. Solar panel(s): Heliocol (set for 7:30am-3:30pm @ 1,500 RPM. For most pools, it's going to be about eight hours. Thank you for your feedback. What Im really needing to know is if the RPMs are good for the size of pool and the length of time Im running each function. Thank you. variable speed pool pentair intelliflo vbestreviews pump Clean the filter and adjust the free chlorine to 2.0. This is the flow meter that we use. Arrow right or left to get to the number you want to make any changes that you want. Overall, we want pool owners to feel comfortable purchasing a new pump knowing they are capitalizing on the most savings. Seems it is set under 2000 and no issues. If you cut your RPMs in half, from 3450 to 1725, you actually get about 75% energy savings.

This is sound advice for a pump of any speed and regular household appliances. Typically, I run that in conjunction with the filter mode for 2 hours a day to get the crud off the water and into the skimmer. Thermal Motors and features and were going to go through features kind of quick because its basically works the same way as everything else, just toggling up and down and making the changes that you need to make, an end of each individual section. To change the value that youre after for example if you want to change this from 2550 to 2500 you would hit select Arrow left two times to the five, push the button down arrow down five times and make a zero, press save and then hit back. With our general rules, guidelines, and tips, you will. does that automate with a pentair easy touch?

Best of all, you'll receive a $10 off coupon for use towards your first order of $149+! document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); 7 Pool Renovation Questions People Dont Ask, Pool pump set for 24 hour cycle on EZ touch, but pool pump not running this morning. In this blog article, we provide tips on how to set up your variable speed pool pump to achieve the greatest performance and energy savings. I might dial my pump speed down a bit. Example: A rectangular 20x40 pool with an average depth of 5 feet. Get the scroll up or down to get to a.m. and p.m. To save your changes when you change your speed it save and back, Then you had a start time where were setting this one to start up at 6 a.m. in the morning. superflo pentair However, in reality, theyre running their variable speed pump below the minimum RPMs. Priming I just lower the speed that it primes at so its not revving up so high. Please consider. In a good way, too. Once you are ready for the pump to go back on switch to Auto mode and the pump will turn back on. We have been experimenting, but havent come up with a satisfactory schedule. Is this overkill? Next is alarm log, this is where we have an issue with the pump shutting down. On the other hand, pool owners use the high-speed settings when the pool needs more flow. I had thought of that, but the last time I tried anything before checking, I had to call pool company to fix. From what I see is the only way to go in and turn the speed up manually then when done turn it down? hayward tristar