American Association for Respiratory Care.

suction catheter airway quizlet management If the patient is on a ventilator, you can either hyperoxygenate and ventilate with the Ambu bag or provide a few extra machine assisted breaths prior to the procedure. (NOTE: The open wrapper or container becomes a sterile field to hold other supplies.) The devices are used to suction oropharyngeal secretions to help prevent aspiration. The Yankauer suction set is an oral suctioning tool used in medical procedures. When performing nasal suctioning, have the patient lean their head backwards to open the airway. Insert the catheter. Hold the catheter between your thumb and forefinger. American Association for Respiratory Care. 2017 Oct;53(4):550-553. doi: 10.1016/j.jemermed.2017.06.003. : The risk for complications rises with each intubation attempt. A: Sterile Yankauer catheters are available for use in medical procedures. We also acknowledge previous National Science Foundation support under grant numbers 1246120, 1525057, and 1413739. Vital signs obtained prior to procedure were heart rate 88 in regular rhythm, respiratory rate 28/minute, and O2 sat 88% on room air. and transmitted securely. The dominant hand will manipulate the catheter and must remain sterile. How frequent should Yankauer suction to be changed. The patient is encouraged to cough during this process. Silver or Chrome plated instruments > 1 year Yankauer; airway management; bougie; difficult airway; difficult intubation; endotracheal intubation; ventilator support. Yankauer with bulb tips are the most common suctioning instrument in the world. Failure of ETI may lead to ineffective ventilation or oxygenation, potentially causing organ damage and eventually death. How much time is taken for suctioning procedure? The tried-and-true method and design of Yankauer devices is why they are the most common suctioning devices in the world. The https:// ensures that you are connecting to the Tungsten Carbide Needle holders > 1 year Epub 2017 Sep 18. Yankauer products are generally sterile unless otherwise specified due to the nature of their indications.

PMC A patient with chronic obstructive pulmonary disease presented to the emergency department in acute respiratory distress. Order was obtained to suction via the nasopharyngeal route. Order was obtained to suction via the nasopharyngeal route. Report any concerns according to agency policy. In many agencies, Yankauer suctioning can be delegated to trained assistive personnel if the patient is stable, but the nurse is responsible for assessing and documenting the patients respiratory status. MeSH 2013 Apr 11-24;22(7):366-8, 370-1. doi: 10.12968/bjon.2013.22.7.366. It comes in a standard size. Remove the supplemental oxygen placed for suctioning, if appropriate. For nasopharyngeal suctioning, gently insert the catheter through the naris and along the floor of the nostril toward the trachea. Background: It eliminates the risk of blockage and cross contamination. Move the bedside table close to your work area and raise it to waist height. Carefully remove the sterile container, touching only the outside surface. Over 2,500,000 satisfied customers since 2000, 7 FDA Approved Air Purifiers for Covid-19. Copyright 2013 Mais India. Titanium instruments > 3 years They will then remove the patients oxygen mask if present and insert the catheter. It can also be used to clear the operative sites during surgery. Additionally, these devices are often used to clear operative sites during surgical procedures. Vitality Medical. Assist the patient to a comfortable position. Coarse rhonchi present over anterior upper airway. A small amount of clear, white, thick sputum was obtained.

Use appropriate listening and questioning skills. This helps guide the catheter toward the trachea rather than the esophagus. Place a small amount of water-soluble lubricant on the sterile field, taking care to avoid touching the sterile field with the lubricant package. It is widely used in a broad range of medical approaches. See Figure \(\PageIndex{2}\)[3]for an image of a sterile suction catheter. By continuing to use this site, you are consenting to our use of cookies. Lippincott procedures. All Rights Reserved. suctioning suction catheter airway yankauer management device figure features thoracickey The patient was unable to be intubated by conventional techniques because of a mass obstructing the view of her vocal cords. There are two types of suctioning, oropharyngeal suctioning and nasopharyngeal suctioning. (2004). Diamond Dust instruments > 1 year The .gov means its official. Legal. Extension tubing is used to attach the Yankauer or suction catheter device to a suction canister that is attached to wall suction or a portable suction source. Any First time Orders which exceed $300.00 or more automatically qualify for free standard shipping (US Only), this excludes Puerto Rico, Hawaii & Alaska. HHS Vulnerability Disclosure, Help

Adjust the suction to the appropriate pressure: Adults and adolescents: no more than 150 mm Hg. These devices are often made with a firm plastic tip with a bulbous opening that's designed to suction without damaging the surrounding tissue. The benefit of the Yankauer bulb-tip design is its ability to suction the area without damaging surrounding tissue. This site uses cookies to help personalize content, tailor your experience and to keep you logged in if you register. JAMA. Tungsten carbide Scissors > 5 years Increase the patients supplemental oxygen level or apply supplemental oxygen per facility policy or primary care provider order. Oronasopharyngeal suctioning. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS? Specifically in the internal human body environment. Pressure should not exceed 150 mm Hg because higher pressures have been shown to cause trauma, hypoxemia, and atelectasis. Yankauer suction set employed for suction purposes like removal of blood, fluids, pus and gas during surgery.

A Yankauer Suction Set consist of catheters, appropriate tubing, and various other compatible accessories. Yankauer suction set is an oral suctioning tool employed for suction purposes like removal of blood, fluids, pus and gas during surgery. Accessibility StatementFor more information contact us atinfo@libretexts.orgor check out our status page at https://status.libretexts.org. FOIA This type of suctioning is performed when oral suctioning with a Yankauer is ineffective. Nasal and pharyngeal suctioning are performed in a wide variety of settings, including critical care units, emergency departments, inpatient acute care, skilled nursing facility care, home care, and outpatient/ambulatory care. Ensure safety measures when leaving the room: BED: Low and locked (in lowest position and brakes on), ROOM: Risk-free for falls (scan room and clear any obstacles). yankauer suction catheter tube device catheters suctioning tracheostomy tracheal rigid rehabmart Super-cut scissors > 1 year. Place the connecting tubing in a convenient location (e.g., at the head of the bed). Coarse rhonchi continued to be present over anterior upper airway but no cyanosis present. Oral Suctioning with Yankauer Suction Catheter (2:53 minutes), Serving more than 2,500,000 satisfied customers since 2000, Vitality Medical7910 South 3500 East Suite CSalt Lake City, Utah 84121. Coarse rhonchi present over anterior upper airway. Apply lubricant to the first 2 to 3 inches of the catheter, using the lubricant that was placed on the sterile field. 2017;49(4):294-302. doi: 10.5603/AIT.a2017.0044. Allow the patient to recover and hyperventilate and hyperoxygenate between each passing of the suction catheter. Copyright 2019 Elsevier Inc. All rights reserved. Case report: If conscious, place the patient in a semi-Fowlers position. The catheter is run along the gum line to the pharynx in a circular motion. Procedure explained to the patient. Yankauer suction catheters are oral suctioning tools used in medical procedures. Prehosp Emerg Care. Br J Nurs. (2020). Successful Retrograde Intubation After Failed Fiberoptic Intubation and Percutaneous Cricothyrotomy.

Reassess the patients respiratory status, including respiratory rate, effort, oxygen saturation, and lung sounds. Replace the oxygen delivery device using your nondominant hand, if appropriate, and have the patient take several deep breaths. The patient should recover for 30-60 seconds between passes.[5]. Don sterile gloves. Before argyle suction yankauer tube without vent capacity tip regular medical flexible Disclaimer: Always review and follow agency policy regarding this specific skill. The stainless body renders the surface inert to many chemical reactions. Keywords: See Figure \(\PageIndex{3}\)[4] for an image of extension tubing attached to a suction canister that is connected to a wall suctioning source. The use of this website is subject to terms and conditions. For nasal suctioning, increase the amount of O2 the patient is receiving for a few minutes prior to the procedure and instruct the patient to take several deep breaths. Suctioning via the oropharyngeal (mouth) and nasopharyngeal (nasal) routes is performed to remove accumulated saliva, pulmonary secretions, blood, vomitus, and other foreign material from these areas that cannot be removed by the patients spontaneous cough or other less invasive procedures. Assess the effectiveness of suctioning by listening to lung sounds and repeat, as needed, and according to the patients tolerance. Lung sounds clear and no cyanosis present. For the best experience on our site, be sure to turn on Javascript in your browser. Epub 2017 Sep 4. Moisten the catheter by dipping it into the container of sterile saline. Unable to load your collection due to an error, Unable to load your delegates due to an error. Vital signs obtained prior to procedure were heart rate 88 in regular rhythm, respiratory rate 28/minute, and O2 sat 88% on room air. Thank you for subscribing, we have sent a special discount coupon on your email address. Disclaimer, National Library of Medicine Approximately 8% of ETIs are difficult and 1% are unsuccessful. Noninvasive ventilation in difficult endotracheal intubation: systematic and review analysis. Advance the catheter approximately 5 to 6 inches to reach the pharynx. Noninvasive positive pressure ventilation was unsuccessful in improving the patient's tidal volume and work of breathing. Suction only on withdrawal and do not suction for more than 10 to 15 seconds at a time to minimize tissue trauma. We can't find products matching the selection. The nurse or assistive personnel who performs suctioning with these devices should use care to protect the patients soft mucous membranes and prevent unnecessary trauma. Olsen Hegar Needle Holder Tungsten Carbide Color Coated, Wire Cutters Tungsten Carbide Color Coated, Bone Cutting Forceps Cardio and Thoracic Instruments, Bulldog Clamps Cardio and Thoracic Instruments, Dissecting Lobectomy Espohageal Scissors Cardio and Thoracic Instruments, Dressing Forceps Cardio & Thoracic Instruments, LUNG GRASPING FORCEPS CARDIO AND THORACIC INSTRUMENTS, Needle Holders Cardio and Thoracic Instruments, Potts-Smith Debakey Scissors Cardio and Thoracic Instruments, Retractors Cardio and Thoracic Instruments, Rib Contactors Cardio and Thoracic Instruments, Rib Shears Cardio and Thoracic Instruments, Thoracic Forceps Cardio and Thoracic Instruments, Tissue Forceps Cardio and Thoracic Instruments, Vascular - Coaraction Clamps Cardio and Thoracic Instruments, Eye Lachrymal Dilators Probes and Accessory Items, Eye Strabismus Tenotomy and Cataract Scissors, Troutman Barraquer Colibri Corneal Forceps, Gynecology Miscellaneous Obstetric Instruments, Gynecology Rotating Shaft Cervical Biopsy Forceps, LEEP/LLETZ Graves Speculum with Smoke Evacuation Tube Coated, LEEP/LLETZ Kogan Endocervial Specula Coated, LEEP/LLETZ Maxi-View Speculum with Smoke Evacuation Tube Coated, LEEP/LLETZ Open Sided Speculum Right with smoke Evacuation Tube Coated, LEEP/LLETZ Pederson Speculum with Smoke Evacuation Tube Coated, LEEP/LLETZ Redundant Wall Vaginal Retractor Coated, LEEP/LLETZ Sterile Disposable Electrodes Coated, Miscellaneous Laryngeal Instruments Mouth and Throat, Drills Burrs Braces and Trephines Neurosurgery, Neurosurgery Clip Applying and Holding Instruments, Miscellaneous Plastic Surgical Instruments, Ligator Cotton Carrier and Suction Tubes Rectal, Dressing and Tissue Forceps Tungsten Carbide Insert, Operating Scissors Super Sharp Tungsten Carbide, Olsen Hegar Needle Holder Left Hand with Scissors, Needle Holders Tungsten Carbide Jaws - Gold Rings, Scissors - Tungsten Carbide Insert Blades, Baumgartner Needle Holder Tungsten Carbide, Click Here See Our All Surgical Instruments, Yankauer Suction Tube 20 Fr Standard Size. An official website of the United States government. Set it up on the work surface and fill with sterile saline using sterile technique. The Yankauer suction tip features a large opening that allows effective suctioning without causing damage to the local tissue. Driver BE, Prekker ME, Klein LR, Reardon RF, Miner JR, Fagerstrom ET, Cleghorn MR, McGill JW, Cole JB.

In the home setting and other community-based settings, maintenance of sterility is not necessary. The user then adjusts the suction to the required level. AARC clinical practice guideline: Nasotracheal suctioning - 2004 revision & update. It is typically a firm stainless suction tip having a large opening. Please enable it to take advantage of the complete set of features! Remove the glove from the nondominant hand and dispose of gloves, catheter, and the container with solution in the appropriate receptacle. Encourage the patient to take several deep breaths. Bethesda, MD 20894, Web Policies LEEP/LLETZ Coated Gynecological Instruments. suction yankauer op flex tapered handles convatec sets continence critical care 2011 Jan-Mar;15(1):30-3. doi: 10.3109/10903127.2010.519821. The following ranges are appropriate pressure according to the patients age: Suction only when clinically indicated and for up to 15 seconds at a time to decrease the risk of respiratory complications. No cyanosis present. Q: Are Yankauer suction catheters sterile? With the dominant gloved hand, pick up the sterile suction catheter. Confirm patient ID using two patient identifiers (e.g., name and date of birth). The nondominant hand is considered clean rather than sterile and will control the suction valve on the catheter. Hyperoxygenation and hyperventilation should be performed prior to the nasal and tracheal procedures to avoid the most common hazards of suctioning (hypoxemia, arrhythmias, and atelectasis). Do not apply suction as the catheter is inserted. It is commonly a firm plastic pull tip with a huge opening encompassed by an adjusted head and is intended to permit powerful attractions without harming encompassing tissue. (OpenRN) via source content that was edited to the style and standards of the LibreTexts platform; a detailed edit history is available upon request. JavaScript seems to be disabled in your browser. doi: 10.1136/bcr-2021-244635. The site is secure. Don additional PPE. Document the procedure and related assessment findings. Apply suction by intermittently occluding the suction valve on the catheter with the thumb of your nondominant hand and continuously rotate the catheter as it is being withdrawn. We hope that knowledge of this novel, yet simple and effective technique will help physicians successfully intubate patients with distorted oropharyngeal anatomy who cannot be intubated using conventional methods.

Remove the oxygen delivery device, if appropriate. Barjaktarevic I, Esquinas AM, West FM, Albores J, Berlin D. Anaesthesiol Intensive Ther. Patient complaining of not being able to cough up secretions. Remove face shield or goggles and mask; perform hand hygiene. A Yankauer device is rigid and has several holes for suctioning secretions that are commonly thick and difficult for the patient to clear. No cyanosis present. Turn off the suction. Open the sterile suction package using aseptic technique. The suction volume counted as blood loss during surgeries. Tools and techniques to successfully obtain airway access are essential. A: The Yankauer is connected to the tubing which connects to the suction machine. suctioning suction catheter airway yankauer management device figure features thoracickey Epub 2010 Nov 10. Yankauer Suction Tube is widely used for suction of oropharyngeal secretions to prevent aspiration. 2018 Jun 5;319(21):2179-2189. doi: 10.1001/jama.2018.6496. This page titled 22.4: Oropharyngeal and Nasopharyngeal Suctioning Checklist and Sample Documentation is shared under a CC BY-SA 4.0 license and was authored, remixed, and/or curated by Ernstmeyer & Christman (Eds.) Raise the bed rail and place the bed in the lowest position. government site.

Low maintenance is required. For tracheal suctioning, do the same. Ensure the patients privacy and dignity. Accessibility Advance the catheter 3 to 4 inches to reach the pharynx. 22.4: Oropharyngeal and Nasopharyngeal Suctioning Checklist and Sample Documentation, [ "article:topic", "license:ccbysa", "showtoc:no", "authorname:ernstmeyerchristman", "Yankauer suction tip", "oropharyngeal suctioning", "program:openrn", "licenseversion:40", "source@https://wtcs.pressbooks.pub/nursingskills" ], https://med.libretexts.org/@app/auth/3/login?returnto=https%3A%2F%2Fmed.libretexts.org%2FBookshelves%2FNursing%2FNursing_Skills_(OpenRN)%2F22%253A_Tracheostomy_Care_and_Suctioning%2F22.04%253A_Oropharyngeal_and_Nasopharyngeal_Suctioning_Checklist_and_Sample_Documentation, \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}}}\) \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{#1}}} \)\(\newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\) \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\) \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\) \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\) \( \newcommand{\Span}{\mathrm{span}}\) \(\newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\) \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\) \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\) \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\) \( \newcommand{\Span}{\mathrm{span}}\), 22.3: Assessments Related to Airway Suctioning, 22.5: Checklist for Tracheostomy Suctioning and Sample Documentation, Checklist for Oropharyngeal or Nasopharyngeal Suctioning, Sample Documentation of Expected Findings, Sample Documentation of Unexpected Findings, https://www.aarc.org/wp-content/uploads/2014/08/09.04.1080.pdf, https://opentextbc.ca/clinicalskills/chapter/5-7-oral-suctioning/, source@https://wtcs.pressbooks.pub/nursingskills, status page at https://status.libretexts.org, Chest auscultation of coarse, gurgling breath sounds, rhonchi, or diminished breath sounds, Reported feeling of secretions in the chest, Suspected aspiration of gastric or upper airway secretions, Clinically apparent increased work of breathing. Patient tolerated procedure without difficulties. document.addEventListener( 'wpcf7mailsent', function( event ) { Yankauer suction supplies is a tracheostomy device used to clear blood, saliva, and other secretions in the airway. It is a reusable tool that can be cleaned and sterilized easily. Because it has high tensile strength and resistance against environmental changes, it is highly compatible with steam sterilization. sharing sensitive information, make sure youre on a federal